Mon. Apr 29th, 2024

5 t/h diesel boiler adopts microcomputer boiler automatic controller, which can realize automatic combustion control, automatic steam pressure control and automatic water level control. Diesel fired steam boilers using automatic burner and monitoring system, greatly reduce the boiler maintenance management workload, and can realize the control of the operation process. In the process of boiler ignition, fuel pressure, fuel temperature, atomized steam pressure, atomized steam temperature and other parameters must meet the requirements of operation procedures. The local observation of good ignition, fire detection back to normal, prohibit short fire detection signal forced into operation.

 

Diesel fired steam boilers
Diesel fired steam boilers

 

To watch after this series of steam boiler ignition furnace smoke temperature, main steam temperature, main steam pressure rise, in smoke after the boiler ignition temperature rise rate significantly slower or smoke temperature does not rise to go on-site inspection immediately fire situation, if found after the fuel into the furnace is not on fire, emergency stop furnace, ventilation was carried out on the chamber of a stove or furnace purging, again without boiler ventilation in oil shall be strictly prohibited.

In the operation of diesel fired boiler, “black furnace” and “main fuel loss protection” must be put into operation according to the requirements of operation regulations. In case the protection device itself fails and needs to be temporarily withdrawn from operation, it can only be implemented with the approval of the manager in charge or the general manager. “Black furnace”, “main fuel loss protection” device out of operation, the duty to focus on monitoring the furnace negative pressure, oxygen, main steam temperature, main steam pressure and other parameters, and through industrial TELEVISION monitoring the furnace fire, if found that the furnace fire, emergency stop furnace. After diesel fired steam boilers is overhauled, transmission test should be carried out on the main protection device of gas boiler according to the requirements of operation regulations. Make sure the primary protection action is correct.

WNS series diesel boiler uses advanced imported burner, leading the world’s combustion technology, combustion, heat exchange effect is good, high thermal efficiency, fuel saving. This series of boiler products adopt high-tech automatic control system, with constant pressure open, shut down, automatic ignition, over pressure power off, flameout automatic protection and other automatic functions, easy to operate. Boiler operation noise is low, does not produce smoke, pollution is small, in line with the national regional environmental protection requirements, is today’s environmental protection requirements of high quality products. Boiler adopts advanced EDA design technology, detailed calculation of furnace body structure and size, effective control of flue gas flow rate and resistance, reasonable full use of flame and flue gas heat exchange, improve the thermal efficiency of the boiler.

 

5T diesel fired boiler
5T diesel fired boiler

 

Diesel fired steam boilers adopts a new design, reduce the emission of harmful substances when fuel combustion, meet the national environmental standards. In particular, reduce nitrogen oxide emissions to meet the national low nitrogen emission standards. Boiler electric control system adopts international brand components to achieve high quality automatic control system. Real-time acquisition of inlet and outlet temperature, pressure and other parameters and real-time centralized display in the control cabinet. Through PID and other closed-loop control system, ensure that the boiler works stably under various parameters set by users. Monitor the working range of each group of data, and remind or alarm all kinds of anomalies, which is convenient for users to use and maintain.
 

Send Message

Leave a Reply

Your email address will not be published. Required fields are marked *