6 Tons horizontal gas steam boilers is a kind of steam boiler, its rated evaporation is 6 Tons/hour, that is to say, it can produce 6 tons of steam per hour. 6 tons horizontal natural gas steam boiler model is WNS6-1.25-Q, WNS refers to the horizontal internal combustion chamber combustion furnace, that is, horizontal steam boiler. The thermal efficiency of horizontal gas fired steam boiler can reach more than 98%, which not only saves the fuel cost, but also reduces the emission of harmful gases and reduces environmental pollution.
6 tons of gas steam boiler gas consumption calculation should first know two values: boiler thermal efficiency 98%, natural gas calorific value: 8500Kcal, and then according to the calculation formula: Gas consumption per hour = boiler effective heat absorption ÷(calorific value of natural gas × boiler thermal efficiency) 6 tons gas consumption per hour = boiler effective heat absorption +(calorific value of natural gas × boiler thermal efficiency).
Horizontal gas steam boilers adopts horizontal three – return wet – back structure design. The boiler has the characteristics of full combustion, high thermal efficiency, large output, strong load adaptability, high degree of automation, safe and reliable operation. This series of boiler products is an ideal environmental protection, high efficiency, low energy consumption boiler products. The combustor of this series of gas-fired boilers adopts the structure design of large corrugated furnace, which not only strengthens the disturbance of flue gas, but also increases the radiation heat transfer area. At the same time, the heat transfer effect is increased and the combustion of fuel in the furnace is promoted. In addition, the stiffness of the furnace is increased, which effectively weakens the expansion stress of the furnace.
Gas fired steam boiler combustor with large volume design, combustion more fully. High heat transfer coefficient screw pipe is used to enhance the effect of convection heat transfer, reduce the exhaust temperature, and effectively improve the thermal efficiency of the boiler. The condensers of this series of boilers are made of ND steel with good corrosion resistance and full threaded finned tube structure, which can significantly increase the heating area and achieve remarkable thermal efficiency. The thermal efficiency can reach more than 97% without converting the sensible heat of condensation, which significantly saves fuel cost for users. Gas fired boiler front smoke box adopts integral double door setting, smoke box door double seal, the form of good integrity, beautiful, generous, maintenance is also very light open. The height of the chimney is 8 meters. The user should determine the actual height according to the requirements of the impact report approved by the local door, but not less than 8 meters.
Horizontal gas steam boilers heating area according to the high design configuration, fully absorb effective heat, low exhaust temperature, small heat loss, ensure sufficient output, high efficiency. The boiler is equipped with movable front and rear smoke box cover, which makes the boiler easy to repair. The series of steam boiler chimney should be added rain cap, the weight of the chimney should not fall directly on the boiler main engine chimney pipe. Boiler hydrostatic test The boiler body and the main pipeline shall be installed after the hydrostatic test. Hydrostatic test should be carried out when the ambient temperature is higher than 5℃, and anti-freezing measures must be taken when the temperature is lower than 5℃. Hydrostatic test water is generally 20-70℃.